Laserfiche WebLink
044 <br />NUMBER:90712CN0001 <br />DATE: 09/07/2012 <br />PRICES VALID FOR 30 DAYS. <br />FINAL PAYMENT DUE UPON COMPLETION <br />PROPOSAL <br />Lead: Previous Customer <br />TAX ID# 26- 3858928 <br />Customer: <br />LEE COUNTY <br />Rep: <br />Building R Grounds Division <br />Set up negative air scrubber per NAMP guidelines. <br />805 S. 5th Street <br />EA <br />Sanford, NC 27331 <br />Phone: <br />919- 718 -4622 <br />Cell: <br />919- 353 -2088 <br />Email: <br />russell.spivey @Ieecountync.gov <br />Branch: <br />Moldstoppers of Central NC, LLC <br />Rep: <br />Patrick Tighe <br />Set up negative air scrubber per NAMP guidelines. <br />P.O. Box 2268 <br />EA <br />Southern Pines, NC 28388 <br />Phone: <br />910- 246 -1371 <br />Cell: <br />910 - 986 -0687 <br />Fax: <br />910- 246 -2015 <br />Email: <br />patrick.tighel @gmail.com <br />Project: 133 South Horner Remediation <br />Office # 5 <br />133 South Horner <br />Sanford, NC 27331 <br />Notes: -All work performed according to ANSI /IIRC 5520 and NAMP (National Association of Mold Professionals) guidelines. <br />-This estimate does not cover the demolition or rebuilding of any damaged structural components that maybe discovered during this remediation. <br />- Complete HVAC System Duct Cleaning by a ACR Specialist (Air System Cleaning Specialist). <br />- Certified by the NADCA (National Air Duct Cleaners Association). <br />- Following ACR 2006 guidelines (Assessment, Cleaning, and Restoration of HVAC Systems. <br />REMEDIOTInN <br />SCOPE OF WORK: <br />- Take Initial Air samples to verify current conditions. <br />- Set up negative air scrubber and vent to outside to avoid dust and debris amplification. <br />- Remove water damaged building materials specified below, bag and discard per NAMP guidelines. <br />- Apply spray fungicide, allow to dry, scrub and sand water damaged building structure and dehumidify. <br />- Apply moldBLOCKT- with 20 year warranty to open structural material as specified below. <br />- Apply spray fungicide from ceiling to floor and wipe down. <br />- HEPA vacuum as needed. <br />- Set up GT3000 Air Purifier and Set AWAY MODE.(Unit must not be entered for 24 hours.) <br />- Complete HVAC decontamination from registers to ducts under negative pressure. <br />- Allow 48 hours prior to clearance testing without fans or HVAC air movement. <br />- Initiate Clearance Air Sampling all rooms. <br />- If results are a Level 1, release building for rebuilding by others. <br />DUCT CLEANING SCOPE OF WORK: <br />Estimate covers Air Duct and Air Handler cleaning. <br />Place the supply side of the ductwork under constant negative pressure. <br />Remove and clean all registers. <br />Zone off trunk line and clean with rotary brushes and compressed air. <br />Process repeated on the Return Side of HVAC System. <br />Clean every pan of Air Handler from filters to, interior walls, coils, condensate pan, and squirrel cage fan. <br />Final step will be sanitizing the entire system with Microban® fog spray under constant negative pressure <br />Qty' <br />M i sc Room _ -' Offi ce '#5` <br />Set up critical air barriers per containment to isolate remediation areas. <br />1 <br />EA <br />Set up negative air scrubber per NAMP guidelines. <br />1 <br />EA <br />Remove and dispose carpet and pad per NAMP guidelines <br />300 <br />SQ FT <br />Remove drywall from contaminated area from bottom edge up 4', bag and dispose per NAMP <br />guidelines. <br />240 <br />SO FT <br />Apply fungal cleanser, wash and scrub contaminated wall studs. <br />240 <br />SO FT <br />Apply moldBLOCK with 20 year warranty to walls. <br />240 <br />SID FT <br />Duct cleaning and AC unit wipe down per unit. <br />1 <br />EA <br />Fungal cleanser wipe down <br />300 <br />SQ FT <br />Fungal cleanser fogging. 1 <br />3001 <br />SO FT <br />Continued >>> <br />Page 112 <br />