3 '9 <br />(a) Every habitable room in a dwelling or dwelling unit shall contain a window or windows facing <br />outside and the total glass area of such window or windows shall not be less than eight percent <br />(8%) of the floor area of such room Windows shall be maintained in accordance with Section 4- <br />78(c). <br />(b) Open-able window area in each habitable room shall be equal to at least one-half of the minimum <br />required window area and open directly to the outside unless the room is served by an approved <br />ventilating system. This requirement does not apply to emergency egress windows froth sleeping <br />rooms as required in Section 4-73(a). <br />(c) All operable and open-able windows shall be adequately screened. Screens shall not be <br />permanently fixed to the window frame or sash. All operable or open-able exterior doors shall <br />have either a screen door or a storm door, equipped with a self-closing device. When approved <br />by the Inspector, the screens on windows and doors may be omitted for dwelling units containing <br />a permanently installed heating and air conditioning system providing the dwelling unit with year <br />round mechanical ventilation. Screens shall be installed in dwellings with window air <br />conditioning units which are not permanently installed. <br />(d) Window frames and glass shall be reasonably weather-tight, with no cracked or broken glass. <br />(e) Each toilet room and bathroom shall have an operable window unless served by other approved <br />ventilation- <br />(f) Each dwelling unit must provide two remote exits or if only one exit is provided, every sleeping <br />room must have at least one open-able window approved for emergency egress. The window <br />must be operable from the inside without use of key or tool- "Ibe window sill height shall not <br />exceed 44" above the floor. Such window shall provide a minimum clear opening width of 20" <br />and a minimum clear opening height of 22"_ The total net clear opening shall not be less than <br />four (4) square feet. Bars, grills or other obstructions placed over these windows must be <br />releasable or removable from the inside without the use of a key or tool. <br />(g) Every public hall and inside stairway in every dwelling or multifamily dwelling shall be <br />adequately lighted at all times to permit safe passage. <br />See. 4-78. Structural Standards. <br />(a) Foundations: <br />(1) The foundation shall be on firm, reasonably dry ground, and there shall be no water standing <br />or running under the building. <br />(2) All elements of the foundation including piers, underpinning and masonry shall be in good <br />repair. Piers shall be sound. <br />(3) T"here shall be sound footings on adequate bearing soil. <br />(4) There shall be no wood stiff knees or other improper piers- <br />(5) No isolated masonry pier shall exceed (10) times the least dimension. <br />(6) Units, when underpinned, shall use an approved material so as to be substantially weather <br />and rodent proof A crawl space access, with cover, shall be provided to Ore under floor <br />space. Adequate ventilation shall be provided to the foundation area by approved methods- <br />